VMEBUS MADC 2508 Product Description The MADC 2508 is a dual height (6U) single width VME module which digitises 32 differential or 64 single–ended voltage signals with 16 bits resolution. Digitised values are stored in a 128K word memory. Scans of a programmed number of inputs are triggered either at programmed rates from 100kHz down to 10Hz, by hardware handshake or by soft trigger. The ADC has a good linearity and the ability to wait for amplifier settling times, according to programmed gain settings, before digitising commences. Features
Use of Address Modifiers
AM29 - Access configuration registers. Memory The 128k x 16 bit SRAM is located in extended (a32) address space. The memory offset is set by the value stored in the memory offset configuration register bits 2–15.
|
Configuration Registers
The configuration registers occupy 64 bytes in the short address space above the base address which is determined by printed circuit
board address jumpers. These are mapped as follows:–
BA+3E Channel 32 Descriptor Channel 31 Descriptor Read/Write
BA+22 Channel 4 Descriptor Channel 3 Descriptor
Read/Write
BA+20 Channel 2 Descriptor Channel 1 Descriptor
Read/Write
BA+16 Trigger
Rate
Read/Write
BA+14 Number of Scans to
Trigger
Read/Write
BA+10 CA Pointer
MS
Read/Write
BA+0E CA Pointer
LS
Read/Write
BA+0A Channels per
scan
Read/Write
BA+08 Memory
attributes
Read
BA+06 Memory
offset
Read/Write
BA+04 Control &
status
Read/Write
BA+02 Device
type
Read
BA+00
Identifier/Vector
Read/Write
Data Formats
Channel Descriptors
DB0
DB8 Gain 1
DB1 DB9 Gain 2
DB2 DB10 Gain 3
DB3 DB11 Filter Enable
DB4 DB12 Delay 1) 0=0S 1=2S
DB5 DB13 Delay 2) 2=4S 3=8S
DB6 DB14 Unipolar/Bipolar
DB7 DB15 +/–
Trigger Rate
D3–D0 A 4–bit code which defines the rate from 10Hz to 100kHz. Code 0
selects external/soft trigger. Code 15 disables trigger.
Number of Scans
DB15–DB0 A 16–bit value which sets the number of scans before interrupt.
Conversion Address
DB0 - DB3 Most significant bits of the Address.
DB0 - DB15 Least significant bit of the Conversion Address.
BT Pointer
DB15–DB0 The least significant 16bits of the Block Transfer Address Pointer.
Vector
DB15–DB0 An 8 or 16–bit value determines the interrupt vector value.
Channels per scan
DB7–DB0 Values of 1 to 64 determine the number of channels to be scanned.
Memory Attributes
DB15 and DB14 are asserted as a 1 to indicate
RAM.`
DB13 is asserted as a 1 to indicate accessibility is both non–privileged and
supervisory.
DB12 is asserted as 0 to indicate block transfer capability.
DB11 is asserted as a 1 to indicate non–protected mode.
DB10, DB9 are asserted as 0 and DB8 is asserted as a 1 to indicate 50–99ns
speed.
DB7–0 are asserted as 1s.
Memory Offset
DB15 to DB2 determine the memory offset mapped
onto A31 to A18.
DB1 and DB0 are not used.
Control and Status
DB15 Scan done. Selected number of scans
completed.
DB14 Reserved.
DB13 12 bit conversion data when set to 1. Default 16 bits.
DB12 Loop back to zero at end of scan.
DB11 Differential mode enable when set to 1.
DB10 Connect reference to the input when set to 1.
DB9 Soft trigger. Trigger preset number of scans.
DB8 ARM enables acquisition when set to 1.
DB7 Interrupt enable when 1.
DB6 Memory full. Interrupt if enabled.
DB5 Single scan. When set to 1 a single scan is enabled for each trigger.
DB4 )
DB3 ) Three bits set interrupt priority level.
DB2 )
DB1 Logic 1. The module does not drive Sysfail.
DB0 Writing a 1 resets the module. Reading a 1 means that acquisition is
occurring.
Device Type
DB11–DB0 define the device code = 2508.